Uploaded image for project: 'Jenkins'
  1. Jenkins
  2. JENKINS-54623

Jenkins changes config.xml but doesn't pick up the changes on restart

      I am experiencing a strange issue.  My configuration details are as follows:

      OS: ubuntu 16.04

      Jenkins version: 2.150

      I am automating the deployment of Jenkins and pwauth plugin using Ansible.  As part part of my debugging I disabled the security by setting useSecurity to false.

      root@mi-jenkins:/home/vagrant# nano /var/lib/jenkins/config.xml
      root@mi-jenkins:/home/vagrant# ls -l /var/lib/jenkins/config.xml
      rw-rr- 1 jenkins jenkins 6414 Nov 14 12:07 /var/lib/jenkins/config.xml
      root@mi-jenkins:/home/vagrant# head /var/lib/jenkins/config.xml
      <?xml version='1.1' encoding='UTF-8'?>
      <hudson>
      <disabledAdministrativeMonitors>
      <string>jenkins.diagnostics.RootUrlNotSetMonitor</string>
      </disabledAdministrativeMonitors>
      <version>2.150</version>
      <installStateName>RUNNING</installStateName>
      <numExecutors>2</numExecutors>
      <mode>NORMAL</mode>
      <useSecurity>false</useSecurity>

      I then go to the jenkins url and issue a post request of reload, https://<jenkins-url>/reload and the security is disabled however the config.xml file has changed on the server.

      root@mi-jenkins:/home/vagrant# ls -l /var/lib/jenkins/config.xml
      rw-rr- 1 jenkins jenkins 6412 Nov 14 12:09 /var/lib/jenkins/config.xml
      root@mi-jenkins:/home/vagrant# head /var/lib/jenkins/config.xml
      <?xml version='1.1' encoding='UTF-8'?>
      <hudson>
      <disabledAdministrativeMonitors>
      <string>jenkins.diagnostics.RootUrlNotSetMonitor</string>
      </disabledAdministrativeMonitors>
      <version>2.150</version>
      <installStateName>RUNNING</installStateName>
      <numExecutors>2</numExecutors>
      <mode>NORMAL</mode>
      <useSecurity>true</useSecurity>

      The irony is that while useSecurity is set to true even after restarting jenkins few times and reloading jenkins I don't see any login screen. I hope this is the correct place to report this bug.

          [JENKINS-54623] Jenkins changes config.xml but doesn't pick up the changes on restart

          Mohammad Ayub created issue -

          Jon Allen added a comment - - edited

          Also can confirm. I have a similar issue. The config.xml reflects the correct values, but  Jenkins settings in the UI does not. Basically after restart Jenkins does not pull PWAuth plugin setting from config.xml

           

          This forces you to disable security, then redo security settings in the UI after every update or restart. Very annoying and a massive security problem.

          Jon Allen added a comment - - edited Also can confirm. I have a similar issue. The config.xml reflects the correct values, but  Jenkins settings in the UI does not. Basically after restart Jenkins does not pull PWAuth plugin setting from config.xml   This forces you to disable security, then redo security settings in the UI after every update or restart. Very annoying and a massive security problem.

            Unassigned Unassigned
            mohammad_ayub Mohammad Ayub
            Votes:
            1 Vote for this issue
            Watchers:
            2 Start watching this issue