Uploaded image for project: 'Jenkins'
  1. Jenkins
  2. JENKINS-47039

Input parameter HTML description displaying escaped

    XMLWordPrintable

Details

    • Bug
    • Status: Resolved (View Workflow)
    • Minor
    • Resolution: Duplicate
    • active-choices-plugin
    • None
    • Jenkins v2.79
      Active Choices Plug v1.53

    Description

      Similar to JENKINS-43380, I'm seeing unresolved HTML tags when using the "Active Choices Reactive Reference Parameter" when HTML is used in the description field. Enabling Markup Formatter = Safe HTML did not resolve the issue.

      Work Around:

      Add
      <j:set var="escapeEntryTitleAndDescription" value="false"/>

      To
      src/main/resources/org/biouno/unochoice/DynamicReferenceParameter/index.jelly

      Attachments

        Issue Links

          Activity

            Thanks for reporting the issue and for including the work around. The same workaround was mentioned in JENKINS-43380, and I tested it and it worked. So closing this one as duplicated as it was reported after JENKINS-43380.

            Preparing a release in the next days, so this should be fixed in the next version of the plugin.

            Thanks again,

            Bruno

            kinow Bruno P. Kinoshita added a comment - Thanks for reporting the issue and for including the work around. The same workaround was mentioned in JENKINS-43380 , and I tested it and it worked. So closing this one as duplicated as it was reported after JENKINS-43380 . Preparing a release in the next days, so this should be fixed in the next version of the plugin. Thanks again, Bruno

            People

              kinow Bruno P. Kinoshita
              mkozell Mike Kozell
              Votes:
              0 Vote for this issue
              Watchers:
              2 Start watching this issue

              Dates

                Created:
                Updated: