• Icon: Bug Bug
    • Resolution: Fixed
    • Icon: Major Major
    • core
    • None

      The Exception:

      Caused by: hudson.util.jna.JnaException: Win32 error: 234 - null
      at hudson.util.jna.RegistryKey.check(RegistryKey.java:124)
      at hudson.util.jna.RegistryKey.getValues(RegistryKey.java:263)

      The getValues handle the 234 error (ERROR_MORE_DATA) but after forget to break the switch-case, so it run to next case (to "default"), which check the error calling the check() function, and that throw an Exception.

          [JENKINS-11767] missing break in getValues@RegistryKey

          Elso Andras created issue -
          SCM/JIRA link daemon made changes -
          Resolution New: Fixed [ 1 ]
          Status Original: Open [ 1 ] New: Resolved [ 5 ]
          R. Tyler Croy made changes -
          Workflow Original: JNJira [ 142010 ] New: JNJira + In-Review [ 189937 ]

            Unassigned Unassigned
            elbandi Elso Andras
            Votes:
            0 Vote for this issue
            Watchers:
            0 Start watching this issue

              Created:
              Updated:
              Resolved: