      slave running on HP Itaniunm B.11.23 U ia64 with java 1.6

      We have a slave running on an HP Itanium host (ver. HP-UX unknown B.11.23 U ia64) where the readlink command does not exists. So when trying to resolve symlinks, slave agent fails with the following error:

      hudson.util.IOException2: java.io.IOException: Cannot run program "readlink" (in directory "/misc/home_tmp_dstk110/."): readlink: not found
      at hudson.FilePath.copyRecursiveTo(FilePath.java:1771)
      at hudson.tasks.ArtifactArchiver.perform(ArtifactArchiver.java:116)
      at hudson.tasks.BuildStepMonitor$1.perform(BuildStepMonitor.java:19)
      at hudson.model.AbstractBuild$AbstractRunner.perform(AbstractBuild.java:711)
      at hudson.model.AbstractBuild$AbstractRunner.performAllBuildSteps(AbstractBuild.java:686)
      at hudson.model.Build$RunnerImpl.post2(Build.java:162)
      at hudson.model.AbstractBuild$AbstractRunner.post(AbstractBuild.java:633)
      at hudson.model.Run.run(Run.java:1463)
      at hudson.model.FreeStyleBuild.run(FreeStyleBuild.java:46)
      at hudson.model.ResourceController.execute(ResourceController.java:88)
      at hudson.model.Executor.run(Executor.java:239)
      Caused by: java.util.concurrent.ExecutionException: java.io.IOException: Cannot run program "readlink" (in directory "/misc/home_tmp_dstk110/."): readlink: not found
      at hudson.remoting.Channel$3.adapt(Channel.java:679)
      at hudson.remoting.Channel$3.adapt(Channel.java:674)
      at hudson.remoting.FutureAdapter.get(FutureAdapter.java:55)
      at hudson.FilePath.copyRecursiveTo(FilePath.java:1769)
      ... 10 more
      Caused by: java.io.IOException: Cannot run program "readlink" (in directory "/misc/home_tmp_dstk110/."): readlink: not found
      at java.lang.ProcessBuilder.start(ProcessBuilder.java:459)
      at java.lang.Runtime.exec(Runtime.java:593)
      at org.jruby.ext.posix.util.ExecIt.run(ExecIt.java:61)
      at org.jruby.ext.posix.util.ExecIt.runAndWait(ExecIt.java:51)

          [JENKINS-14021] HP-UX doesn't have readlink

          Fulvio Cavarretta created issue -
          Fulvio Cavarretta made changes -
          Environment Original: slave running on HP Itaniunm B.11.23 U ia64 with java 1.6 New: Jenkins ver. 1.467.
          slave running on HP Itaniunm B.11.23 U ia64 with java 1.6
          Fulvio Cavarretta made changes -
          Labels Original: hpitanium slave symlink New: hpitanium readlink slave symlink
          Kohsuke Kawaguchi made changes -
          Component/s New: core [ 15593 ]
          Component/s Original: build-publisher [ 15529 ]
          Assignee Original: vjuranek [ vjuranek ]
          Summary Original: readlink not working on HP Itanium New: HP-UX doesn't have readlink
          Jesse Glick made changes -
          Link New: This issue duplicates JENKINS-13202 [ JENKINS-13202 ]
          Jesse Glick made changes -
          Resolution New: Duplicate [ 3 ]
          Status Original: Open [ 1 ] New: Resolved [ 5 ]
          R. Tyler Croy made changes -
          Workflow Original: JNJira [ 144489 ] New: JNJira + In-Review [ 191114 ]

            Unassigned Unassigned
            fcavarretta Fulvio Cavarretta