Bug
-
Resolution: Fixed
-
Major
We have set a Timeout of 10 mins.
If the script is frozen or UFT is not reacting the call: QTPApplication.Test.Stop will never finish.
The plugin in this case, is unable to stop the Execution and wait there ... well for a long time.
If I kill the UFT process manually I get this ( StackTraceIn my case it means that UFT was stuck there for more than a minute)
My proposal is to start a totally separate process that will act like a timebomb. After a specific Timeout it simply kills UFT. This process should be stopped if the Test Case is finished and for each test Execution rescheduled.
C:\work\jenkins\workspace\IEC\TA_IEC_AllTests\IEC\tests\001_change_and_release_management\T0001_R30_TC_Core_CreateCR_and_Derive_CO
[Test Set: 001_change_and_release_management] Running test: C:\work\jenkins\workspace\IEC\TA_IEC_AllTests\IEC\tests\001_change_and_release_management\T0001_R30_TC_Core_CreateCR_and_Derive_CO
[Test Set: 001_change_and_release_management] Error: There was an error reading from the pipe: Die Pipe wurde beendet. (109, 0x6d).
[Test Set: 001_change_and_release_management] at System.RuntimeType.ForwardCallToInvokeMember(String memberName, BindingFlags flags, Object target, Int32[] aWrapperTypes, MessageData& msgData)
[Test Set: 001_change_and_release_management] at QTObjectModelLib.Test.Stop()
[Test Set: 001_change_and_release_management] at HpToolsLauncher.GuiTestRunner.ExecuteQTPRun(TestRunResults testResults)
[Test Set: 001_change_and_release_management] Test result: Error
[Test Set: 001_change_and_release_management] 05.10.2017 17:13:26 Test complete: C:\work\jenkins\workspace\IEC\TA_IEC_AllTests\IEC\tests\001_change_and_release_management\T0001_R30_TC_Core_CreateCR_and_Derive_CO