Bug
-
Resolution: Fixed
-
Major
-
jenkins 2.165 on windows server 2012
warning-ng-plugin 3.0.1
-
-
warnings-ng 3.0.3
A job fail with a java exception. the cause seem to be the Warnings Next Generation.
It happen when the threshold are undefined in the section health report configuration.
the error show is:
ERROR: Build step failed with exception
java.lang.NullPointerException
at io.jenkins.plugins.analysis.core.util.QualityGate.map(QualityGate.java:179)
at io.jenkins.plugins.analysis.core.steps.IssuesRecorder.publishResult(IssuesRecorder.java:617)
at io.jenkins.plugins.analysis.core.steps.IssuesRecorder.record(IssuesRecorder.java:553)
at io.jenkins.plugins.analysis.core.steps.IssuesRecorder.perform(IssuesRecorder.java:516)
at hudson.tasks.BuildStepCompatibilityLayer.perform(BuildStepCompatibilityLayer.java:81)
at hudson.tasks.BuildStepMonitor$3.perform(BuildStepMonitor.java:45)
at hudson.model.AbstractBuild$AbstractBuildExecution.perform(AbstractBuild.java:744)
at hudson.model.AbstractBuild$AbstractBuildExecution.performAllBuildSteps(AbstractBuild.java:690)
at hudson.model.Build$BuildExecution.post2(Build.java:186)
at hudson.model.AbstractBuild$AbstractBuildExecution.post(AbstractBuild.java:635)
at hudson.model.Run.execute(Run.java:1841)
at hudson.matrix.MatrixRun.run(MatrixRun.java:153)
at hudson.model.ResourceController.execute(ResourceController.java:97)
at hudson.model.Executor.run(Executor.java:429)