Uploaded image for project: 'Jenkins'
  1. Jenkins
  2. JENKINS-57178

ERROR: Caught ComException: Maximum timeout of 120 seconds exceeded: COM server not available! and ERROR: Could not determine ECU-TEST version!

    XMLWordPrintable

Details

    Description

      Hi,

      I get these errors when trying to build the ECU test in jenkins. What could be reason for that?

      I checked path in Global Tool Configuration and it's good. I'm using ECU-TEST 7.1.

       

       

       

      Attachments

        Activity

          ayr16:

          You need to register the COM server of your ECU-TEST installation properly.

          In your case run the following command in an elevated cmd with administrator privileges:

          "C:\Program Files\ECU-TEST 7.1\ECU-TEST_COM.exe" /register

          For further information have a look in the FAQ section.

          tracetronic TraceTronic GmbH added a comment - ayr16 : You need to register the COM server of your ECU-TEST installation properly. In your case run the following command in an elevated cmd with administrator privileges: "C:\Program Files\ECU-TEST 7.1\ECU-TEST_COM.exe" /register For further information have a look in the  FAQ section.