Details
-
Bug
-
Status: Resolved (View Workflow)
-
Minor
-
Resolution: Fixed
-
None
-
-
workflow-durable-task-step 2.24
Description
When a workflow is manually aborted in Jenkins it fires a hudson.AbortException. This is the same thing that happens when a step fails. Thus, it's impossible to properly set the build status to ABORTED on a manual abort and to FAILED on a failed step because you can't programmatically tell the difference.
jglick’s recommended fix: see comment as of 2017-06-28
Attachments
Issue Links
- is duplicated by
-
JENKINS-41944 Unable to understand when AbortError is created by user`s action like pressing button Stop
-
- Resolved
-
-
JENKINS-34376 Cannot easily/safely catch exceptions without disrupting job abortion
-
- Resolved
-
-
JENKINS-37724 Record cause of interruption in DurableTaskStep
-
- Resolved
-
- relates to
-
JENKINS-51928 Timeout is caught by the most internal try-catch, but should be caught by the try-catch that surrounds the timeout step
-
- Resolved
-
- links to
Thanks for the info. After updating to 2.21 I can confirm that the issue we faced is fixed.